P-fluorobenzaldehyde, p-chlorobenzaldehyde, p-fluorobenzonitrile, o-fluorobenzonitrile, o-chlorobenzonitrile, p-fluorobenzoyl chloride, p-methoxybenzoyl chloride, m-methylbenzoyl chloride, glycerin, o-chlorobenzoic acid, p-chlorotrichlorobenzene, trichlorotoluene -- Shanghai Yuqing Chemical Technology Co., Ltd

Hotline:+86-18261695669

  • 4-Fluorobenzaldehyde
  • 2- Fluorobenzoyl chloride
  • 2,4-Dichlorobenzaldehyde
  • 2,4-Dichlorobenzonitrile
  • Chloroacetyl chloride
  • 2-Fluorobenzonitrile
  • 4-Fluorobenzoyl chloride
  • Methyl chloroacetate
  • p-Anisoyl chloride
  • 3,5-Dimethylbenzoyl chloride
  • p-Toluoyl chloride
  • m-Toluoyl chloride
  • o-Toluoyl chloride
  • 2-Chlorobenzonitrile
  • o-chlorobenzoic acid
  • 4-Chlorobenzotrichloride
  • Contact us
    Contact: manager Tang 18261695669
    Contact:person: Manager Zhang 13701865101
    Email:719337120@qq.com
    Address:room 1508, No. 2, Lane 289, Zheqiao Road, Pudong New Area, Shanghai

    product

    Methyl chloroacetate

      

    National Standard Number: 61102

    CAS number: 96-34-4

    Product name: methyl chloroacetate

    Molecular formula: C3H5ClO2; ClCH2COOCH3

    Molecular weight: 108.5236 

    Property: Colorless transparent liquid with irritating smell.

    Melting point (℃): -32.1

    Boiling point (℃): 129.8

    Relative density (water = 1): 1.24

    Relative vapor density (air = 1): 3.8

    Saturated vapor pressure (kPa): 1.33 (29℃)

    Critical pressure (MPa): 4.5

    Octanol/water partition coefficient: 0.63

    Flash point (℃): 50.15

    Ignition temperature (℃): 463

    Upper explosion limit (%): 18.5

    Lower explosion limit (%): 7.5

    Solubility: Slightly soluble in water, miscible in ethanol, ether, acetone and benzene.

    Relative density (25℃, 4℃): 1.2281

    Precautions for storage: Store in a cool, ventilated warehouse. Keep away from fire and heat. The storage temperature should not exceed 32°C and the relative humidity should not exceed 80%. Keep container tightly closed. It should be stored separately from oxidants, reducing agents, acids, alkalis and edible chemicals. Use explosion-proof lighting and ventilation facilities. It is forbidden to use mechanical equipment and tools that easily generate sparks. The storage area should be equipped with leakage emergency treatment equipment and suitable containment materials. 

    Copyright(C)2020 , Shanghai Yuqing Chemical Technology Co., Ltd. All Rights Reserved.  Supported by  ChemNet  ChinaChemNet Toocle Copyright Notice